ON MEASURING THE COMPONENTS OF INDUCTIVE IMPEDANCE USING THE THREE VOLTMETER METHOD

Authors

  • Tverdostup Mykola

DOI:

https://doi.org/10.34185/1562-9945-1-150-2024-13

Keywords:

inductance, resistance, impedance, three voltmeter method, measurement, frequency response, quality factor, approximate measure.

Abstract

The possibilities of the three voltmeter method for measuring inductance and its active re-sistance, as well as their frequency characteristics, are investigated. It is established that that in the frequency ange up to 100 kHz, the measurement error of inductance is no more than 0.3%, active resistance - 8.7%, and quality factor - 5%.

References

Oznakomlenie s metodom threh voltmetrov: web-sait.

ULR http//www.vunivere.ru/work 36704 (data zvernennja: 23.08.2023).

Тverdostup N.I. Osobennosti izmereniya induktivnogo impedansa na nizkih tchastotah. Systemni technologii. Dnipropetrovsk, 2016. Vyp. 1(102). S. 87 - 93.

Downloads

Published

2024-04-16